| Model | OLS1000ERT2U |
| Capacity (VA/W) | 1000VA / 900W |
| Typology | Online (Double Conversion) |
| Energy-Saving Technology | Yes, ECO Mode Efficiency > 95% |
| Input | |
| Input Type | IEC C14 |
| Frequency Range | 40~70Hz |
| Output | |
| UPS Outlets (Numbers) | (3+3) IEC C13 |
| On Battery Output Voltage | Pure Sine Wave at 208, 220, 230, 240 VAC (Configurable) |
| On Battery Output Voltage Distortion (@Nominal Battery Voltage) | ≤ 3%(Linear Load), ≤ 5%(Non-Linear Load) |
| On Battery Output Frequency | 50 Hz / 60 Hz (Auto-Sensing or Configurable) ± 0.5% |
| Transfer Time (Typical) | 0ms |
| Overload Protection | AC Mode: Warning only @ 110%>Load>105%, Transfer to bypass after 60sec @ 120%>Load>110%, Transfer to bypass immediately@ Load>120% |
| Battery Mode: Warning only @ 110%>Load>105%, Shutdown after 10sec @ 120%>Load>110%, Shutdown immediately @ Load>120 | |
| Short Circuit Protection | UPS Output Cut off Immediately or Circuit Breaker Protection |
| Surge Protection and Filtering | |
| Surge Protection | Yes |
| DSL/Phone/Fax/Modem protection | RJ11/RJ45 (One In/One Out) |
| Battery | |
| Sealed Maintenance Free Lead Acid Battery | (3) 12V / 7AH |
| Typical Recharge Time | 5 |
| Runtimes | |
| Half load-Full load (mins) | 16-Jun |
| Status Indication | |
| Indicators | Power On, Line Mode, Battery Mode, Bypass Mode, ECO Mode,C/F Mode, Fault, Replace Battery |
| Audible Alarms | Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery |
| Communication | |
| Power Management Software | PowerPanel® Business Edition |
| Management | |
| Self-Test | Yes |
| Auto-Charge/Auto-Restart | Yes |
| Auto-Overload Recovery | Yes |
| Cold Start (DC Start) | Yes |
| Connectivity Ports | Serial Port (RS232), USB Port, EPO/ROO |
| SNMP/HTTP Capable | Optional |
| Dimensions (H x W x D) | 88 x 438 x 430 mm |
| Weight | 13.2 kg |
| Model | OLS1000ERT2U |
| Capacity (VA/W) | 1000VA / 900W |
| Typology | Online (Double Conversion) |
| Energy-Saving Technology | Yes, ECO Mode Efficiency > 95% |
| Input | |
| Input Type | IEC C14 |
| Frequency Range | 40~70Hz |
| Output | |
| UPS Outlets (Numbers) | (3+3) IEC C13 |
| On Battery Output Voltage | Pure Sine Wave at 208, 220, 230, 240 VAC (Configurable) |
| On Battery Output Voltage Distortion (@Nominal Battery Voltage) | ≤ 3%(Linear Load), ≤ 5%(Non-Linear Load) |
| On Battery Output Frequency | 50 Hz / 60 Hz (Auto-Sensing or Configurable) ± 0.5% |
| Transfer Time (Typical) | 0ms |
| Overload Protection | AC Mode: Warning only @ 110%>Load>105%, Transfer to bypass after 60sec @ 120%>Load>110%, Transfer to bypass immediately@ Load>120% |
| Battery Mode: Warning only @ 110%>Load>105%, Shutdown after 10sec @ 120%>Load>110%, Shutdown immediately @ Load>120 | |
| Short Circuit Protection | UPS Output Cut off Immediately or Circuit Breaker Protection |
| Surge Protection and Filtering | |
| Surge Protection | Yes |
| DSL/Phone/Fax/Modem protection | RJ11/RJ45 (One In/One Out) |
| Battery | |
| Sealed Maintenance Free Lead Acid Battery | (3) 12V / 7AH |
| Typical Recharge Time | 5 |
| Runtimes | |
| Half load-Full load (mins) | 16-Jun |
| Status Indication | |
| Indicators | Power On, Line Mode, Battery Mode, Bypass Mode, ECO Mode,C/F Mode, Fault, Replace Battery |
| Audible Alarms | Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery |
| Communication | |
| Power Management Software | PowerPanel® Business Edition |
| Management | |
| Self-Test | Yes |
| Auto-Charge/Auto-Restart | Yes |
| Auto-Overload Recovery | Yes |
| Cold Start (DC Start) | Yes |
| Connectivity Ports | Serial Port (RS232), USB Port, EPO/ROO |
| SNMP/HTTP Capable | Optional |
| Dimensions (H x W x D) | 88 x 438 x 430 mm |
| Weight | 13.2 kg |
Hotline bán hàng VP Hà Nội:
0983.366.022Hotline bán hàng VP Hồ Chí Minh:
0904.672.691VP Hà Nội:
0983.366.022Chi nhánh Hồ Chí Minh:
0904.672.691Hỗ trợ kỹ thuật:
0986.862.595Hỗ trợ bảo hành:
0977.893.186Chúng tôi tự hào về những cột mốc và kết quả đã
đạt
được, phản
ánh sự tin tưởng và hợp
tác
bền vững từ đối tác và khách hàng trong suốt hành trình phát triển.
+
Năm kinh nghiệm
+
dự án hoàn thành
%
khách hàng hài lòng
+
giải thưởng công nghệ
Đừng để hạ tầng công nghệ là điểm yếu kìm hãm doanh nghiệp. Trao đổi ngay với chuyên gia của CDC Technologies để tối ưu hệ thống CNTT, hỗ trợ tăng trưởng an toàn và bứt phá!
Để lại thông tin, CDC Technologies sẽ liên hệ tư vấn cấu hình, báo giá hoặc giải pháp phù hợp.
Ngân hàng Thương Mại Cổ Phần Tiên Phong - Chi nhánh Hà Nội
Ngân hàng TMCP Ngoại thương Việt Nam - Chi nhánh Sở Giao Dịch
Ngân hàng TMCP Quân đội - Chi nhánh Thăng Long
Ngân hàng TMCP Kỹ thương Việt Nam - Chi nhánh Chương Dương
CDC Technologies cung ứng thiết bị CNTT cho doanh nghiệp, tập trung tư vấn và cung cấp thiết bị phù hợp với nhu cầu vận hành. CDC Technologies đồng hành cùng doanh nghiệp trong chuẩn hóa hạ tầng thiết bị, tối ưu chi phí đầu tư và duy trì trải nghiệm sử dụng ổn định.
Công ty Cổ Phần Công Nghệ CDC. Theo giấy phép ĐKKD số 0105801222. Ngày cấp 23/02/2012 do Sở kế hoạch và đầu tư thành phố Hà Nội cấp. Đại diện pháp luật: Phạm Tuấn Dũng
Hỏi và đáp (0 bình luận)